Spot supply of the new Yokogawa EJA530E high-performance pressure transmitter (direct installation)
The Yokogawa EJA530E high-performance pressure transmitter is the next model in the Chongqing Chuan Instrument
Key words:
pressure
transmitter
Classification:
Pressure transmitter
Yokogawa EJA Transmitter
MANUALS & GUIDES :
Hotline:
Detailed introduction

Yokogawa EJA530E High-Performance Pressure TransmitterIt is the next model in the Chongqing Chuan Instrument Yokogawa EJA Transmitter-E series, a directly mounted, high-performance gauge/absolute pressure transmitter. It uses single crystal silicon resonant sensor technology, suitable for measuring the pressure of liquids, gases, or steam. The Yokogawa EJA530E high-performance pressure transmitter (directly mounted) converts pressure into a 4-20mA DC current signal output, featuring fast response, remote setting, self-diagnosis, and other functions. The Yokogawa EJA smart transmitter is a new product from Yokogawa Electric Corporation's DPharp series, which first adopts digital sensors—single crystal silicon resonant sensors. The sensor outputs a pair of differential digital signals, directly eliminating external interference in the sensor part, creating a new era for transmitters. The product has higher accuracy (±0.055%), greater stability, and reliability, and has received widespread acclaim since its market launch.
Here’s a distilled list of the key features of the Yokogawa EJA530E high-performance pressure transmitter:
High Accuracy: Standard ±0.055% of span; optional ultra-high accuracy of ±0.04%
Exceptional Stability: ±0.1% of URL per 10 years for minimal recalibration needs
Fast Response: 90 ms response time—ideal for dynamic process control
Signal Customization: 10-point linearization for complex process curves (e.g., tank strapping, flow correction)
Safety Ready: SIL2/SIL3 certified (per IEC61508) by Exida and TÜV—suitable for safety instrumented systems (SIS)
Advanced Display: Local indicator with configurable graphical/textual info, independent of 4–20 mA signal
Robust Construction: Designed for in-line gauge pressure measurement in harsh industrial environments
Comms Flexibility: HART 7 protocol standard; FOUNDATION Fieldbus and PROFIBUS options available
Global Certifications: Explosion-proof, intrinsically safe, and flameproof approvals for global use
Product specifications of the Yokogawa EJA530E pressure transmitter:
| Parameter | Specification |
|---|---|
| Transmitter Type | In-line mounted gauge pressure transmitter |
| Accuracy | ±0.055% of span (standard), ±0.04% (optional) |
| Stability | ±0.1% of URL per 10 years |
| Response Time | 90 milliseconds |
| Output Signal | 4–20 mA DC with superimposed digital signal (HART 7) |
| Optional Protocols | FOUNDATION™ Fieldbus, PROFIBUS® PA |
| Power Supply | 10.5–42 V DC (HART), 10.5–32 V DC (Fieldbus/PROFIBUS) |
| Range Limits | Varies by capsule; e.g., 0.5 kPa to 10 MPa |
| Process Temperature | –40°C to +120°C (with silicone oil fill fluid) |
| Ambient Temperature | –40°C to +85°C |
| Display | Local indicator with graphical/textual interface |
| Certifications | SIL2/SIL3 (Exida, TÜV), explosion-proof, intrinsically safe, and flameproof |
| Mounting | Direct in-line mounting |
| Material | SUS316L, Hastelloy C, others depending on wetted parts configuration |
Selection specifications and common models of the Yokogawa EJA530E pressure transmitter:
model | Specification code | explain |
EJA530E | Pressure transmitter | |
output signal | - D | 4-20mA DC BRAN protocol |
- J | 4-20mA DC HART 5/HART7 protocol | |
- F | Refer to GS01C31T02-01CN for FF fieldbus protocol | |
- G | Refer to GS01C31T02-01CN for the PROFIBUSPA bus protocol | |
- Q | 1-15V DC low-power HART7 protocol | |
Measurement range (Capsule) | A | 10~200kPa(1.45~29Psi) |
B | 0.1~2MPa(14.5~290Psi) | |
C | 0.5~10MPa(72.5~1450Psi) | |
D | 5~50MPa(720~7200Psi) | |
Material of the liquid receiving part | Process joint membrane, other | |
S | 316L SST Hastelloy C-276 316LSST | |
H | Hastelloy C-276 Hastelloy C-276 Hastelloy C-276 | |
Process connection | 4 | 1/2NPT internal thread |
7 | 1/2NPT external thread | |
8 | G1/2 DIN 16288 external thread | |
9 | M20X1.5 DIN 16288 external thread | |
---- | N | Usually N |
---- | -0 | Usually 0 |
Amplifier casing | 1 | Cast aluminum alloy |
3 | Corrosion resistant cast aluminum alloy | |
2 | ASTM CF-8M stainless steel | |
Electrical connection | 0 | G1/2 internal thread, one electrical interface without blind plug |
2 | 1/2NPT internal thread, two electrical interfaces without blind plugs | |
4 | M20 internal thread, two electrical interfaces without blind plugs | |
5 | G1/2 internal thread, two electrical interfaces with a blind plug | |
7 | 1/2NPT internal thread, two electrical interfaces with a blind plug | |
9 | M20 internal thread, two electrical interfaces with a blind plug | |
A | G1/2 internal thread, two electrical interfaces with one SUS316 blind plug | |
C | 1/2NPT internal thread, two electrical interfaces with one SUS316 blind plug | |
D | M20 internal thread, two electrical interfaces with one SUS316 blind plug | |
Built in display table | D | Digital display table |
E | Digital display table with range setting switch | |
N | nothing | |
2-inch pipeline installation bracket | L | SUS316 |
N | No installation bracket |
Frequently Asked Questions – Yokogawa EJA530E
1. What type of pressure does the EJA530E measure?
It measures gauge pressure and is designed for in-line mounting in process systems.
2. What is the standard accuracy of the EJA530E?
It offers a standard accuracy of ±0.055% of span, with an optional upgrade to ±0.04% for ultra-high precision.
3. Is the EJA530E suitable for safety instrumented systems (SIS)?
Yes, it is SIL2/SIL3 certified by both Exida and TÜV, making it suitable for use in safety-critical applications.
4. What communication protocols are supported?
The standard model supports HART 7, with optional support for FOUNDATION Fieldbus and PROFIBUS PA.
5. Can the output signal be customized for non-linear applications?
Absolutely. It supports 10-point signal characterization, ideal for applications like tank strapping or non-linear flow correction.
6. What is the response time?
The transmitter responds in 90 milliseconds, making it suitable for fast-changing process conditions.
7. What kind of display does it have?
It features a local indicator that can show graphical and textual data, independent of the 4–20 mA output.
8. What is the operating temperature range?
Ambient: –40°C to +85°C
Process: –40°C to +120°C (with silicone oil fill)
9. What materials are available for wetted parts?
Options include SUS316L, Hastelloy C, and others depending on the application and process compatibility.
10. Where can I find official documentation and manuals?
You can access datasheets, manuals, and configuration tools on .
Friendly reminder:The selection parameters for the Yokogawa EJA530E high-performance pressure transmitter (directly mounted) are numerous. If you want complete product selection and model pricing, please feel free to call (029-84516813) for online inquiries.
Common models:
| Model Code | Capsule Type | Output Signal | Process Connection | Electrical Connection | Mounting | Other Notes |
|---|---|---|---|---|---|---|
| EJA530E-DAS4N-09DE | D (Low range) | A (4–20 mA + HART) | S (1/2 NPT female) | 4 (G1/2 female, ISO) | N (None) | Standard config |
| EJA530E-EAS4N-09DE | E (Mid range) | A (4–20 mA + HART) | S (1/2 NPT female) | 4 (G1/2 female, ISO) | N (None) | Higher pressure range |
| EJA530E-DBS4N-09DE | D (Low range) | B (Fieldbus) | S (1/2 NPT female) | 4 (G1/2 female, ISO) | N (None) | Digital protocol |
| EJA530E-EBS4N-09DE | E (Mid range) | B (Fieldbus) | S (1/2 NPT female) | 4 (G1/2 female, ISO) | N (None) | Digital protocol, mid range |
| EJA530E-DCS4N-09DE | D (Low range) | C (PROFIBUS PA) | S (1/2 NPT female) | 4 (G1/2 female, ISO) | N (None) | PROFIBUS version |
| EJA530E-ECS4N-09DE | E (Mid range) | C (PROFIBUS PA) | S (1/2 NPT female) | 4 (G1/2 female, ISO) | N (None) | PROFIBUS, higher range |
| EJA530E-DDS4N-09DE | D (Low range) | D (4–20 mA + HART, advanced diagnostics) | S (1/2 NPT female) | 4 (G1/2 female, ISO) | N (None) | Enhanced diagnostics |
| EJA530E-EDS4N-09DE | E (Mid range) | D (4–20 mA + HART, advanced diagnostics) | S (1/2 NPT female) | 4 (G1/2 female, ISO) | N (None) | Enhanced diagnostics, mid range |