Yokogawa EJA440E high-pressure pressure transmitter
The Yokogawa EJA440E high-pressure pressure transmitter (traditional installation) is the next model in the Chongqing Chuan Instrument Yokogawa EJA transmitter-E series
Key words:
pressure
transmitter
Classification:
Pressure transmitter
Yokogawa EJA Transmitter
MANUALS & GUIDES :
Hotline:
Detailed introduction

The Yokogawa EJA440E high-pressure pressure transmitter (traditional installation) is the next traditional installation high-pressure intelligent pressure transmitter in the Chongqing Chuan Instrument Yokogawa EJA transmitter-E series, and is an upgraded model of the Yokogawa EJA440A high-pressure transmitter. The Yokogawa EJA440E high-pressure transmitter also uses the most advanced single crystal silicon resonant sensing technology, making it very suitable for pressure measurement of liquids, gases, or steam. The Yokogawa EJA440E high-pressure pressure transmitter (traditional installation) converts the measured differential pressure into a 4-20mA DC current signal output, featuring fast response, remote setting, and self-diagnosis functions. The Yokogawa EJA-E series products provide communication protocols such as BRAIN, HART/HART (1~5VDC) low power type, FF fieldbus, and PROFIBUS PA, with standard configuration certified by SIL 2 safety certification.
key features of the Yokogawa EJA440E high-pressure gauge transmitter that make it a standout in industrial applications:
High Accuracy: ±0.055% of span, ensuring precise pressure measurements
Long-Term Stability: ±0.1% of URL over 10 years, reducing recalibration needs
Fast Response Time: 90 milliseconds for quick process feedback
Digital Sensor: DPharp resonant silicon sensor offers superior performance over analog types
SIL 2/3 Certified: Certified by Exida and TÜV for use in safety instrumented systems
Local Parameter Setting (LPS): Configure the device without a handheld communicator
Multiple Protocols: Supports HART 5/7, FOUNDATION Fieldbus, PROFIBUS PA, and BRAIN
Signal Characterization: Allows custom output curves for non-linear applications
Wide Pressure Range: Up to 50 MPa (7200 psi), suitable for high-pressure systems
Robust Construction: Hastelloy C-276 diaphragm and stainless steel body for corrosion resistance
Integral Digital Indicator: Optional display with or without range-setting switch
1. Parameters and specifications of the Yokogawa EJA440E high-pressure pressure transmitter:
| Parameter | Specification |
|---|---|
| Model | EJA440E |
| Measurement Type | High-pressure gauge pressure |
| Sensor | DPharp resonant silicon |
| Accuracy | ±0.055% of span |
| Stability | ±0.1% of URL over 10 years |
| Response Time | 90 ms |
| Pressure Range | Up to 50 MPa (7200 psi) |
| Output Signal | 4–20 mA DC with HART (5/7), BRAIN, Fieldbus, PROFIBUS PA |
| SIL Rating | SIL 2/3 (certified by Exida and TÜV) |
| Material (Wetted Parts) | Hastelloy C-276 diaphragm; SUS316L body |
| Process Connection | 1/2–14 NPT or ANSI/IEC-compatible flanges |
| Display | Optional digital LCD with or without setting switch |
| Power Supply | 10.5–42 V DC (depends on protocol) |
| Configuration | Local Parameter Setting (LPS), or via communicator |
| Ambient Temperature Range | –40 to +85°C (–40 to +185°F) |
| Explosion Protection | FM, ATEX, IECEx, NEPSI, etc. |
2. Functions and features of the Yokogawa EJA440E high-pressure pressure transmitter:
Here’s a simplified version that keeps the key points clear and crisp:
Smart Sensor Monitoring: The DPharp sensor always sends out signals—even when pressure is steady—so if it fails, the transmitter knows right away.
High Accuracy with Real-Time Compensation: It measures pressure and temperature simultaneously and adjusts readings instantly to stay accurate, even with environmental changes.
Combined Measurement: One transmitter can measure both differential and static pressure, cutting equipment costs by up to 20%.
Flexible Output Tuning: With 10-point signal curve adjustment, it fits non-linear setups like tank levels or flow measurement.
Advanced Diagnostics: Features 40 health checks—including Yokogawa's patented “Back-Check” reverse calculation—to detect internal issues early. Plus, it uses an active sensor that’s always “talking,” so silence means a problem.
Built-In Overpressure Protection: Both sensor and internal parts are designed to resist accidental pressure spikes, guarding against damage.
Certified Safety (SIL 2/3): Designed per IEC standards, it meets strict functional safety requirements for critical systems—with or without redundancy.
Globally Certified: Proven performance and safety verified by TÜV Rheinland and EXIDA.
3. Selection specifications for the Yokogawa EJA440E high-pressure pressure transmitter:
model | Specification code | explain |
EJA440E | ..................................... | Pressure transmitter |
Output signal | - D ................................. | 4~20mA DC BRAN protocol |
- J ................................. | 4~20mA DC HART 5/HART7 protocol“ | |
- F ................................. | Refer to GS 01C31T02-01CN for FF fieldbus protocol | |
- G ................................. | PROFIBUS PA bus protocol refer to GS 01C31T04-01CN | |
- Q ................................. | 1-5V DC low-power HART7 protocol | |
Measurement range (membrane box) | C ............................... | 5~32MPa(720~4500psi) |
D ............................... | 5~50MPa(720~7200psi) | |
Material of the liquid receiving part "2 | S ............................... | Refer to the "Materials for Liquid Receiving Parts" table |
Process connection | 3 ............................... | Process connector with 1/4 NPT internal thread * 3 * 4 |
4 ............................... | Process connector with 1/2 NPT internal thread * 3 * 4 | |
5 ............................... | No process joint (with 1/4NPT internal thread on the chamber flange) * 3 | |
Material of bolts and nuts | J ............................... | B7 |
G ............................... | 316L SST | |
C ............................... | 660 SST | |
install | -3 ............................... | Vertical installation, high voltage on the right side, process connected at the bottom |
-7 ............................... | Vertical installation, high voltage on the left side, process connected at the bottom | |
-8 ............................... | Horizontal installation, high voltage on the right side | |
-9 ............................... | Horizontal installation, high voltage on the left side | |
-U ............................... | Universal type | |
Amplifier casing | 1 ............................... | Casting aluminum alloy |
3 ............................... | Corrosion resistant cast aluminum alloy * 5 | |
2 ............................... | ASTM CF-8M Stainless Steel * 6 | |
Electrical connection | 0 ............................... | G1/2 internal thread, one electrical interface without blind plug |
2 ............................... | 1/2NPT internal thread, two electrical interfaces without blind plugs | |
4 ............................... | M20 internal thread, two electrical interfaces without blind plugs | |
5 ............................... | G1/2 internal thread, two electrical interfaces with a blind plug * 7 | |
7 ............................... | 1/2 NPT internal thread, two electrical interfaces with a blind plug * 7 | |
9 ............................... | M20 internal thread, two electrical interfaces with a blind plug * 7 | |
A ............................... | G1/2 internal thread, two electrical interfaces with one SUS316 blind plug | |
C ............................... | 1/2 NPT internal thread, two electrical interfaces with one SUS316 blind plug | |
D ............................... | M20 internal thread, two electrical interfaces with one SUS316 blind plug | |
Built in display table | D ............................... | Digital display table * 8 |
E ............................... | Digital display table with range setting switch * 9 | |
N ............................... | (No header) | |
2-inch pipeline installation bracket | A ............................... | SECC flat bracket |
B ............................... | 304 SST flat bracket | |
C ............................... | SECC L-shaped bracket | |
D ............................... | 304 SST L-shaped bracket | |
K ............................... | 316 SST flat bracket | |
N ............................... | 316 SST L-shaped bracket none | |
Additional specification code | □/Additional specifications | |
Friendly reminder:The price of the new Yokogawa EJA440E high-pressure pressure transmitter (traditional installation) mainly depends on the specific quotation after you select the model specifications. If you need online product selection and model quotation, please feel free to call for detailed inquiries.
Frequently Asked Questions – Yokogawa EJA440E
1. What type of pressure does the EJA440E measure?
It measures gauge pressure in high-pressure applications—ideal for liquids, gases, or steam.
2. What’s the accuracy of the EJA440E?
It offers ±0.055% of span accuracy, making it one of the most precise in its class.
3. What is DPharp and why is it important?
DPharp is Yokogawa’s digital resonant silicon sensor. It continuously outputs signals, enabling real-time diagnostics and higher reliability compared to analog sensors.
4. Can it handle overpressure events?
Yes. It has built-in mechanical and sensor-level overpressure protection, safeguarding it from pressure surges or valve misoperations.
5. Is it suitable for safety systems?
Absolutely. It’s SIL 2/3 certified by TÜV and Exida, compliant with IEC 61508 and 61511 standards.
6. What communication protocols are supported?
It supports HART 5/7, FOUNDATION Fieldbus, PROFIBUS PA, and BRAIN protocols.
7. Can I configure it without a communicator?
Yes. The Local Parameter Setting (LPS) feature allows basic configuration directly on the device.
8. What’s the benefit of composite sensing?
It can measure both differential and static pressure in one unit, reducing the need for multiple transmitters and saving on CAPEX.
9. How does signal characterization work?
It allows 10-point curve customization of the 4–20 mA output, ideal for non-linear applications like tank levels or flow.
10. What diagnostics are available?
It includes 40 self-diagnostic functions, including Yokogawa’s patented Back-Check reverse calculation for internal consistency.
Regular models:
| Model Code |
|---|
| EJA440E-DCS5J-917NC |
| EJA440E-JCS4G-912DA |
| EJA440E-JCS4J-312DN |
| EJA440E-ECS4A-97D(N)A |
| EJA440E-JCS4J-917EA/NS2 |
| EJA440E-DCS4J-812DA |
| EJA440E-DCS4J-912EA |
| EJA440E-DCS4J-912DA |
| EJA440E-JCS4J-912EA |
| EJA440E-JCS4J-912DA |
| EJA440E-DDS4J-912EA |
| EJA440E-DDS4J-912DA |
| EJA440E-JDS4J-912EA |
| EJA440E-JDS4J-912DA |
Immediate Consultation
If you are interested in our products, please leave your email, we will contact you as soon as possible, thank you!