Fisher DVC6200 Valve Positioner
The functions of the Fisher 6000 series valve positioner include: A high-performance, non-linkage feedback system that eliminates component wear by not requiring direct contact. Fully encapsulated electronic components that can withstand vibration, high temperatures, and corrosive environments. The ability to respond quickly to significant step changes and to precisely control slight setpoint variations.
Key words:
Classification:
Fisher Locator
MANUALS & GUIDES :
Hotline:
Detailed introduction

Here are the key features of the Fisher FIELDVUE DVC6200 digital valve positioner that make it a standout in industrial control:
Linkage-less, non-contact feedback: Eliminates mechanical wear by using magnetic field sensing, improving reliability and extending service life.
Encapsulated electronics: Protects against vibration, temperature extremes, and corrosive environments—ideal for harsh field conditions.
Two-stage pneumatic relay: Delivers fast response to large setpoint changes and precise control for small adjustments.
Travel control fallback: If position feedback fails, it automatically switches to pressure control to keep the valve operational.
Advanced diagnostics: Monitors valve health and performance in real time, enabling predictive maintenance and reducing downtime.
Modular design: Allows for easy replacement of components without disturbing field wiring or tubing.
HART communication: Enables remote configuration, calibration, and diagnostics, reducing the need for field exposure.
Integrated position transmitter/switch options: Eliminates the need for separate accessories, saving on hardware and installation costs.
Specifications of Fisher 6000 Series Valve Positioner:
| Parameter | Specification |
|---|---|
| Input Signal | 4–20 mA DC (HART-enabled) |
| Supply Pressure | 2.0 to 6.0 bar (30 to 100 psig), depending on actuator requirements |
| Air Consumption | Approx. 0.06 Nm³/hr (2.1 scfh) at 1.4 bar (20 psig) |
| Output Pressure | Up to supply pressure |
| Ambient Temperature Range | –40°C to +85°C (–40°F to +185°F), varies by model and certification |
| Enclosure Rating | IP66 / NEMA 4X |
| Communication Protocol | HART (also available in FOUNDATION Fieldbus and Profibus variants) |
| Mounting | Linkage-less, magnetic feedback; adaptable to rotary and linear actuators |
| Certifications | FM, CSA, ATEX, IECEx, NEPSI, and others for hazardous locations |
| Diagnostics | Valve Signature, Step Response, Travel Deviation, and more |
| Fail-Safe Mode | Travel control fallback to pressure control in case of feedback failure |
Frequently Asked Questions – Fisher DVC6200
1. What is the DVC6200 used for?
It’s a digital valve controller that receives a 4–20 mA signal and adjusts the valve position accordingly. It enhances control accuracy, provides diagnostics, and supports remote configuration via HART.
2. What makes it “linkage-less”?
Instead of mechanical linkages, it uses magnetic field sensing for position feedback. This reduces wear and improves long-term reliability.
3. Can it be used in hazardous environments?
Yes. It’s certified for use in hazardous areas with approvals like FM, ATEX, IECEx, and NEPSI.
4. What communication protocols are supported?
The standard model supports HART, but variants are available for FOUNDATION Fieldbus and Profibus PA.
5. How does it support diagnostics?
It offers real-time valve health monitoring, including travel deviation, step response, and valve signature analysis—ideal for predictive maintenance.
6. What happens if the position feedback fails?
It automatically switches to pressure fallback mode, maintaining control using actuator pressure instead of travel feedback.
7. Is it compatible with rotary and linear actuators?
Yes. Its modular design and magnetic feedback system allow mounting on both types, including remote-mount configurations.
8. How is it configured?
You can use Emerson’s AMS Device Manager, handheld communicators (like the 475), or other HART-compatible tools for setup and calibration.
9. What’s the difference between DVC6200 and DVC6200f/p/SIS?
DVC6200f: FOUNDATION Fieldbus version
DVC6200p: Profibus PA version
DVC6200 SIS: Designed for Safety Instrumented Systems (SIL-rated)
10. Can it be used with wireless adapters?
Yes. It supports Emerson’s Smart Wireless THUM™ Adapter for wireless diagnostics and configuration.
Previous Page
Next Page
Immediate Consultation
If you are interested in our products, please leave your email, we will contact you as soon as possible, thank you!