Rosemount 2240S Multi-Input Temperature Transmitter
The highly stable high-performance 2240S multi-point temperature transmitter has been certified for applications requiring trade handover, which need to measure liquid levels and temperatures very precisely to calculate net standard volume. The Rosemount 2240S can connect up to sixteen 3-wire or 4-wire temperature point elements and an integrated level sensor. It provides the average liquid temperature based on each single-point temperature element combined with the corresponding level value for net volume calculation. Its temperature conversion accuracy is outstanding, reaching ± 0.05 °C (± 0.09 °F).
Key words:
Classification:
Rosemount temperature transmitter
MANUALS & GUIDES :
Hotline:
Detailed introduction

The highly stable high-performance 2240S multipoint temperature transmitter has been certified for applications requiring trade handover, which need to measure liquid levels and temperatures very precisely to calculate net standard volume. The Rosemount 2240S can connect up to sixteen 3-wire or 4-wire temperature point elements and an integrated level sensor.
It provides the average liquid temperature based on each single point temperature element combined with the corresponding level value, for net volume calculations. Its temperature conversion accuracy is excellent, reaching ± 0.05 °C (± 0.09 °F).
Here’s a crisp breakdown of the key features of the Rosemount 2240S Multi-Input Temperature Transmitter—perfect for a banner or summary card:
Multi-Input Capability: Supports up to 16 3- or 4-wire RTD sensors, enabling precise temperature profiling.
High Accuracy: Delivers exceptional temperature accuracy of ±0.05 °C over the full measurement range.
Integrated Water Level Sensor: Built-in functionality for free water interface level detection in storage tanks.
Foundation™ Fieldbus Protocol: Ensures seamless digital communication and system compatibility.
Robust Design: Operates reliably from -40 °C to +70 °C (startup at -50 °C), suited for challenging environments.
Custody Transfer Certified: Compliant with OIML R85:2008 and API Chapter 7.3, ideal for fiscal metering.
Companion Compatibility: Interfaces with Rosemount 2410 tank hubs and temperature sensors like 565/566/765.
Power Efficiency: Supports intrinsically safe two-wire bus systems (FISCO or Entity).
| Parameter | Specification |
|---|---|
| Sensor Inputs | Up to 16 RTD inputs (3- or 4-wire Pt-100, Cu-90) |
| Temperature Accuracy | ±0.05 °C (±0.09 °F) across the full measuring range |
| Measuring Range | -200 to 250 °C (-328 to 482 °F) |
| Integrated Water Level | Yes — free water interface level detection |
| Communication Protocol | Foundation™ Fieldbus (includes emulation for legacy compatibility) |
| Certifications | OIML R85:2008, API Chapter 7.3 compliance |
| Compatible Devices | Works with Rosemount 2410, 565, 566, and 765 models |
| Environmental Limits | Operating: -40 to +70 °C; Startup: -50 °C |
| Power Supply | Intrinsically safe two-wire bus (FISCO or Entity) |
| Sensor Standards | IEC/EN 60751, ASTM E1137 |
FAQ section for the Rosemount 2240S Multi-Input Temperature Transmitter:
Frequently Asked Questions (FAQ)
1. What types of sensors can the 2240S connect to?
It supports up to 16 RTD sensors, including 3- or 4-wire Pt-100 and Cu-90, conforming to IEC/EN 60751 and ASTM E1137 standards.
2. Can it measure water level inside storage tanks?
Yes, it has an integrated water level sensor designed to detect free water interface levels, supporting inventory management in tank gauging systems.
3. Is the 2240S suitable for custody transfer applications?
Absolutely. It is OIML R85:2008-certified and supports API Chapter 7.3 calculations, making it highly reliable for fiscal metering.
4. What communication protocol does it use?
The 2240S communicates via Foundation™ Fieldbus, with backward compatibility through emulation modes for legacy systems.
5. What power supply does it require?
It operates on a two-wire intrinsically safe bus, compliant with FISCO or Entity models, ensuring safe performance in hazardous areas.
6. What’s the environmental operating range?
It functions reliably from -40 °C to +70 °C, and can start up at temperatures as low as -50 °C.
7. Which devices are typically paired with the 2240S?
Common companions include Rosemount 2410 Tank Hub, and temperature sensors like the 565, 566, and 765 series.
Previous Page
Next Page
Immediate Consultation
If you are interested in our products, please leave your email, we will contact you as soon as possible, thank you!