Emerson has launched its first non-contact radar level transmitter specifically for the food and beverage industry.



To meet the high demand for high precision and reliability in the field of hygiene and safety, Emerson recently launched the first non-contact radar device specifically designed for the food and beverage industry - the Rosemount™ 1408H Level Transmitter. This level transmitter features a hygienic compact design, fast scanning technology, excellent radar beam focusing, and IO-Link communication, providing accurate non-contact measurements that help optimize equipment operation and ensure food safety. It assists manufacturers in improving operational efficiency, reducing product loss, and ensuring food safety.
Non-contact radar is an ideal level measurement technology suitable for applications that require strict hygiene facilities and equipment. In stark contrast to traditional technologies, non-contact radar is essentially maintenance-free or requires very little maintenance, helping to ensure long-term reliability. Its top-down installation method reduces the risk of product loss due to leaks and is unaffected by process conditions such as density, viscosity, temperature, and pH. The compact and robust design of the Rosemount 1408H makes it an ideal solution for use in small tanks and space-restricted skids in food and beverage production. Its hygienic antenna is flush with the process connection, ensuring that process residues can be removed during in-situ cleaning and disinfection, and it is less prone to condensation and accumulation. This IP69-rated device meets hygiene certification, has a stainless steel housing with minimal seams, can withstand external rinsing, and ensures cleanliness.
The Rosemount 1408H is the first level transmitter to use 80 GHz frequency-modulated continuous wave technology on a single electronic chip with embedded intelligent algorithms. It achieves excellent radar beam focusing, avoiding blockages in internal tanks caused by agitators, and provides higher measurement accuracy. The fast scanning technology makes the Rosemount 1408H one of the fastest level measurement technologies on the market, with information collection efficiency over 40 times that of traditional transmitters. This significantly improves measurement accuracy while reducing product loss due to waste, greatly increasing production capacity, reducing production variability, and enhancing product quality and batch consistency. Additionally, the technology can measure from the bottom to the top of the tank, avoiding radar dead zones and helping users improve tank utilization.
The Rosemount 1408H is the first non-contact radar transmitter that can connect with the IO-Link communication protocol, allowing for easy integration with automation systems. It not only provides traditional 4-20 mA switch outputs and digital high-speed communication but also features innovative technology and intelligent algorithms that simplify installation and commissioning, saving time and ensuring smooth operation of the equipment. When used with the new Rosemount IO-Link Assistant software (for setting parameters via IO-Link), it further enhances the user experience of Rosemount IO-Link devices.
Melissa Stiegler, Director of Hygienic Business for Emerson Measurement Solutions, stated: "The Rosemount 1408H is the latest product in Emerson's measurement equipment series, designed with the requirements of hygiene and safety applications in mind. This level transmitter meets the stringent safety requirements of the food and beverage industry, reducing the risk of contamination, while its accuracy and reliability ensure the production of high-quality products that meet consumer expectations, making it an ideal alternative to traditional technologies."
The Rosemount 1408H received the 2021 Red Dot Award for Product Design due to its innovative design. The Red Dot Award is an annual international award evaluated by a jury of engineering and design professionals who select outstanding products for their design and innovation from thousands of new products.


Related News


How to Choose the Right Temperature Transmitter in 2026? Is Rosemount 248 Temperature Transmitter a Reliable Choice?

Temperature measurement is an important and fundamental feature of most industrial process control. So how do you choose the correct temperature transmitter for reliable temperature measurement and detection?


DVC2000 vs DVC6200: What’s the Difference Between Fisher FIELDVUE Digital Valve Positioners?

Both Fisher DVC2000 Digital Valve Positioner and Fisher DVC6200 Digital Valve Positioner are perhaps two-star products in Emerson's Fisher FIELDVUE product range.


Understanding the Working Process of Fisher FIELDVUE DVC2000 Digital Valve Controller

Fisher FIELDVUE DVC2000 is a digital valve controller. It is fed with a 4-20mA control signal and then the commands are processed by means of a microcontroller.


How To Choose The Right DP Transmitter? Is Rosemount 2051CD Differential Pressure Transmitter A Good Choice?

Differential pressure transmitters are a critical part of flow measurement systems. If you use the wrong transmitter, your measurements will be inaccurate, your processes will not run smoothly, and you may even shut down.


Rosemount 2088 Pressure Transmitter or Rosemount 3051 Transmitter-Which One Is Right For Me?

The selection of pressure transmitters for industrial processes often puts engineers in a dilemma between the Rosemount 2088 and the Rosemount 3051.


How Does Yokogawa YTA710 Dual Input Temperature Transmitter Work? YTA710 Working Principle Explained

Yokogawa YTA710 Smart Temperature Transmitter is a best-selling smart temperature transmitter produced by Japan Yokogawa.